Three-component high-temperature adhesive, how to select product H31000?
Hits: 692
img
One cannot simply rely on the fact that product H31000 has a temperature resistance of 800-1000°C or a bonding strength greater than 12 MPa at room temperature to directly conclude that it is suitable for all metal, ceramic or composite material bonding and sealing systems. Product H31000 is a gray-black three-component, solvent-free silazane type adhesive. One must first confirm the type of substrate, surface treatment, the proportion and mixing sequence of the three components, the homogeneity of the mixture, the shelf life, the thickness of the adhesive layer, the curing temperature curve, the operating temperature and atmosphere, the thermal cycling conditions, and the sealing structure before determining whether the problem lies in poor interface wetting, deviation in the proportion of the three components, improper mixing, incomplete curing, high-temperature shrinkage, oxidation, or adhesive layer defects, or poor compatibility with the substrate and working conditions. Product H31000 can be considered as a candidate for medium-high temperature silazane type adhesives, but it must be verified through small-scale tests, bonding strength tests, and actual high-temperature working conditions.
1. Why does the strength of three-component silazane type adhesives often decrease in high-temperature bonding or sealing?
The surface of the substrate is not cleaned or is contaminated with oil, release agents, oxide layers, or dust, which affects the wetting of the adhesive by the metal, ceramic or composite material and the interface bonding.
The three components are not accurately measured according to the effective TDS proportion, or the mixing sequence, stirring method is improper, resulting in incomplete curing in some areas, insufficient crosslinking density, or inconsistent ceramic behavior at high temperatures.
The applicable period of the three-component mixture is not controlled properly, causing the adhesive to thicken or react prematurely, affecting the uniformity of coating, interface wetting and final strength.
The adhesive viscosity is approximately 3000 cp. If the coating thickness or layer thickness is improper, when it is too thick, high-temperature shrinkage and thermal mismatch increase, and when it is too thin, insufficient filling.
The curing was not carried out according to the furnace heating to 170°C, curing for 2 hours, and furnace cooling, resulting in incomplete curing or the generation of internal stress.
Using temperatures exceeding 800-1000°C, or repeatedly expanding and contracting in high-temperature and low-temperature cycles, the adhesive layer develops microcracks and gradually expand.
The high-temperature atmosphere control is improper, such as oxidation of the adhesive layer or substrate in an oxidative atmosphere, resulting in a decrease in interface strength.
When switching from phosphate-based adhesives, organic silicon adhesives, borosilazane, polycarbosilane or other silazane type adhesives, the surface treatment, proportion of the three components, layer thickness and curing curve are not re-adjusted, resulting in deviations from the target strength.
In the sealing structure, the adhesive layer is subjected to pressure, shear and thermal cycling, and only the room temperature or single temperature strength data is selected without verifying the actual sealing conditions.
The opening of the product or prolonged storage may result in ammonia gas leakage, poor ventilation affecting the operating environment, and may also mask changes in the adhesive material state.
Storage conditions not meeting the requirements of cool and dry, sealed storage or exceeding the shelf life of 1 year result in a decrease in adhesive material activity, fluctuations in curing quality and high-temperature strength.
The understanding of data with a 400°C bonding strength greater than 4 MPa and a 600°C bonding strength greater than 3 MPa is insufficient. The strength decreases with increasing temperature, and it is not designed according to actual load and safety factors.
2. Determine which stage the problem of high-temperature bonding or sealing occurs
Failure stage Possible causes Preferred inspection direction
The adhesive layer does not wet or has local lack of adhesive after coating Unclean substrate, high viscosity of the adhesive, improper coating amount Surface treatment, adhesive viscosity, coating amount
The adhesive layer thickens or the applicable period is insufficient after the three-component mixture Proportion deviation, improper mixing sequence, prolonged storage Three-component measurement, mixing sequence, applicable period
Insufficient room temperature bonding strength after curing Deviation in the curing curve, thick adhesive layer, interface contamination Heating curve, adhesive layer thickness, substrate treatment
The 400°C bonding strength is lower than 4 MPa Incomplete curing, thermal mismatch, adhesive layer defect Curing quality, thermal expansion matching, adhesive layer uniformity
The 600°C bonding strength is lower than 3 MPa High-temperature shrinkage, oxidation, microcrack expansion Operating atmosphere, thermal cycling, structural design
The strength rapidly decreases from 800 to 1000℃ Exceeding the material's applicable temperature, ceramicization shrinkage, oxidation Operating temperature, atmosphere, load-bearing design
The adhesive layer cracks or detaches after thermal cycling Thermal expansion coefficient difference, overly thick adhesive layer, rapid heating Thermal expansion matching, adhesive layer thickness, heating and cooling rate
Leakage in the sealing structure Adhesive layer discontinuity, pores, interface detachment Coating process, curing curve, sealing structure
The ammonia smell is obvious or the adhesive material thickens after opening the lid Improper storage conditions, long-term storage, poor sealing Storage temperature, container sealing, usage period
Fluctuations in strength or curing behavior between batches Three-component batch differences, ratio or coating instability Incoming inspection, ratio records, curing curve records
If only focusing on "whether product H31000 was used", without recording substrate treatment, three-component ratio, mixing sequence, adhesive layer thickness, curing curve, usage atmosphere and thermal cycling conditions, it is usually difficult to accurately determine whether it is a material problem or a process problem.
Three, why increasing the curing temperature or increasing the adhesive layer thickness may not be effective?
Product H31000 plays a role as a high-temperature resistant adhesive in the bonding system. It is affected by the substrate, three-component ratio, mixing uniformity, adhesive layer thickness, curing curve, usage temperature and atmosphere. Simply increasing the temperature or increasing the thickness may bring side effects.
Increasing the curing temperature may accelerate curing, but exceeding the recommended curve may cause increased adhesive layer shrinkage, internal stress concentration or substrate damage.
Extending the curing time may improve the curing degree, but it may affect production efficiency and is ineffective for contaminated, expired or unevenly mixed adhesive materials.
Increasing the adhesive layer thickness may improve the filling capacity, but too thick will increase high-temperature shrinkage and thermal mismatch, reducing the bonding strength.
Reducing the adhesive layer thickness may reduce thermal stress, but it may lead to missing adhesive, pores or discontinuous sealing.
When the substrate surface is not cleaned, only adjusting the curing temperature or adhesive layer thickness cannot solve the interface wetting and bonding problem.
When the three-component ratio deviation or mixing is uneven, only adjusting the curing curve cannot restore the crosslink density and high-temperature strength.
When high-temperature oxidation or thermal cycling causes microcracks, only increasing the curing temperature cannot restore the strength.
When the adhesive is expired or its activity decreases, only adjusting the process cannot restore the original performance.
If the mixture is applied beyond the applicable period, only adjusting the curing conditions cannot restore fluidity and interface wetting.
Therefore, when optimizing, one should observe substrate treatment, three-component ratio, mixing sequence, adhesive layer viscosity, adhesive layer thickness, curing curve, usage atmosphere and thermal cycling conditions, rather than only adjusting a single parameter.
Four, what are the differences in product selection between H31000 and H21000, H11500, H21500 and similar high-temperature adhesive schemes?
Comparison direction Product H31000 (three-component silazane type) Product H21000 (two-component silazane type) Product H11500 (single-component borosilazane type) Product H21500 (two-component polycarbon silane type) Selection boundary
Temperature range Marked as 800 to 1000℃ in the data Marked as 1000 to 1100℃ in the data Marked as 1300 to 1500℃ in the data Marked as greater than 1500℃ in the data High-temperature working conditions require selecting the actual temperature
Number of components Three-component Two-component Single-component Two-component Three-component requires more strict control of ratio and mixing sequence
Appearance Grey black Grey black Grey Grey Choose based on appearance and construction requirements
Viscosity Approximately 3000 cp 1000 to 3000 cp 3000 to 4000 cp 3000 to 4000 cp Choose based on coating process
Curing temperature: Furnace heating to 170℃ for 2 hours, furnace heating to 170℃ for 2 hours, furnace heating to 170℃ for 2 hours, 220℃ for 2 hours. It depends on the substrate's temperature resistance and the production line.
Room temperature bonding strength: Greater than 12 MPa, greater than 8 MPa, greater than 5 MPa, greater than 10 MPa. It needs to be selected according to the load requirements.
400℃ strength: Greater than 4 MPa, not specified, 400℃ shear greater than 8 MPa, not specified. It needs to be compared according to the temperature nodes.
500-600℃ strength: 600℃ greater than 3 MPa, 600℃ pull-off greater than 2 MPa, 800℃ shear greater than 8 MPa, 500℃ pull-off greater than 15 MPa. It needs to be selected according to the actual high-temperature load.
900-1000℃ strength: 1000℃ applicable upper limit, 1000℃ pull-off greater than 1 MPa, 1000℃ shear greater than 8 MPa, 900℃ shear greater than 15 MPa, above 1000℃ requires assessment of higher temperature resistance models.
Solvent-free: Yes, Yes, Yes, Yes. Solvent-free requirements prioritize this series.
Ammonia emission: Opening the cover or prolonged placement may cause ammonia leakage. May cause ammonia leakage. May cause ammonia leakage. Not specially marked. Ventilation operation is required.
Storage conditions: Cool and dry, with a shelf life of 1 year. Cool and dry, with a shelf life of 1 year. Cool and dry, with a shelf life of 1 year. Cool and dry, with a shelf life of 1 year. It needs to be managed according to the storage conditions.
Five. What parameters should be confirmed when using product H31000?
Parameter category: Application direction - metal bonding, ceramic bonding, composite material bonding, sealing, high-temperature resistant coating; substrate type - metal, ceramic, composite material and surface condition; surface treatment - cleaning method, degreasing, oxide removal, drying degree.
Three-component ratio: Confirm the ratio according to the effective TDS, and measure the accuracy of each component in three groups.
Mixing sequence: Order of adding the three components, mixing method, mixing time.
Gel application period: Time for use after mixing, viscosity change and coating window.
Coating process: Coating amount, coating layer thickness, uniformity, whether multiple coatings are required.
Curing curve: Furnace heating to 170℃, curing for 2 hours, furnace cooling.
Operating temperature: Long-term temperature, peak temperature, exposure conditions at 800-1000℃.
Operating atmosphere: Air, inert gas, vacuum, oxidizing or reducing atmosphere.
Thermal cycling: Heating and cooling rate, number of cycles, high and low temperature holding time.
Sealing structure: Gap, pressure, loading method, leakage requirements.
Storage conditions: Cool and dry, sealed, shelf life of 1 year.
Acceptance indicators: Room temperature bonding strength, 400℃ and 600℃ bonding strength, sealing performance, strength retention rate after thermal cycling.
Six. What should be mainly verified when using product H31000?
Three-component measurement accuracy, mixing sequence and mixing uniformity.
Applicable period of the mixed gel and coating window.
Wetting property of the substrate surface after treatment and continuity of the coating layer.
Whether the curing curve is executed as furnace heating to 170℃, curing for 2 hours, furnace cooling.
Whether the room temperature bonding strength is greater than 12 MPa.
Whether the 400℃ bonding strength is greater than 4 MPa.
Whether the 600℃ bonding strength is greater than 3 MPa and evaluate the safety factor for 800-1000℃ load.
The influence of coating layer thickness on bonding strength and thermal mismatch.
The strength retention rate and interface integrity after thermal cycling.
The impact of operating atmosphere on gel layer oxidation and sealing performance.
The consistency of bonding between different substrates of metal, ceramic and composite materials.
The leakage rate and pressure holding capacity of the sealing structure.
The impact of ammonia emission from opening the cover and ventilation conditions on operation.
The consistency of gel viscosity, curing behavior and high-temperature strength among batches of three-component gel.
Seven. How to design experiments before using product H31000?
Establish a benchmark for the current high-temperature resistant adhesive, record the model, surface treatment, ratio, mixing sequence, layer thickness, curing curve and failure performance.
Uniform test conditions: substrate, surface treatment, three sets of ratios, mixing sequence, mixing method, layer thickness, curing curve, operating temperature, atmosphere and thermal cycling conditions.
Set candidate samples: current adhesive, product H31000, different layer thickness or curing curve gradients.
Complete the full process test: surface treatment → three-component metering → sequential mixing → coating → curing → room temperature strength → high-temperature bonding strength → thermal cycling → sealing test.
Evaluate actual results: room temperature strength, 400℃ and 600℃ bonding strength, strength retention rate after high-temperature, sealing performance.
Test items Uniform requirements
Substrate and surface treatment Keep consistent or set gradients according to the test design
Three-component ratio Confirmed and kept consistent according to the effective TDS
Mixing sequence and method Set gradients according to the test design
Layer thickness Set gradients according to the test design
Curing curve Set gradients based on the 170℃×2h benchmark
Operating temperature Set according to 400/600℃ and 800-1000℃
Operating atmosphere Set according to actual working conditions
Thermal cycling conditions Set according to the actual heating and cooling rate and cycling times
Measurement method Consistent for room temperature strength, bonding strength, sealing performance, and strength retention rate after thermal cycling
Eight. Which situations are not suitable for directly using product H31000?
If the substrate surface is not cleaned or has oil stains, oxide layer, or release agent, it will affect the interface bonding.
The three-component ratio cannot be accurately controlled according to the effective TDS, or the mixing sequence and stirring are not uniform.
After mixing, it cannot be coated and assembled within the applicable period.
The curing curve cannot be executed according to the furnace heating to 170℃, curing for 2 hours, and furnace cooling.
If the operating temperature exceeds 800-1000℃ for a long time, the high-temperature creep and oxidation have not been evaluated.
The operating atmosphere is strong oxidizing, and the antioxidant ability of the adhesive layer and substrate has not been verified.
The sealing structure can withstand high pressure or strong vibration, and the actual sealing working condition has not been verified.
If specific food contact, medical or airworthiness approval is required, but the corresponding data has not been obtained.
Only have the operating temperature, but no substrate, three-component ratio, mixing sequence, layer thickness, curing curve and atmosphere data.
The customer requests to directly mix into the in-use system, but the surface treatment, ratio, mixing, coating and curing conditions cannot be controlled.
When switching from phosphate, organic silicon, borosilicon nitrogen, polycarbon silicon, or other silicon nitrogen adhesives, the process needs to be re-adjusted.
Storage conditions do not meet the requirements of cool and dry, or exceed the 1-year shelf life.
Poor ventilation in the operating environment, ammonia gas overflow from opening the lid affects the health of the operators.
The safety factor and high-temperature strength attenuation near 1000℃ have not been evaluated.
Ten. What selection support can our company provide?
As a solution provider for the entire organic silicon industry chain, our company can assist in comparing the applicability of three-component silicon nitrogen adhesives in different substrates, three-component ratios, mixing sequences, layer thicknesses, curing curves and high-temperature conditions for product H31000.
For projects that need to balance metal, ceramic or composite material bonding and sealing, as well as high-temperature coating preparation, before selection, the following should be provided:
Application direction and substrate type.
Target room temperature bonding strength and 400-600℃ bonding strength.
Surface treatment method.
Three-component ratio, mixing sequence and applicable period requirements.
Layer thickness and coating process.
Curing curve and heating and cooling conditions.
Operating temperature, atmosphere and thermal cycling requirements.
Sealing structure, pressure and leakage requirements.
Current adhesive model, process and failure performance.
Acceptance method and applicable standards.
After receiving the complete materials, it can be determined whether to test a certain formulation of product H31000 for its compatibility, mixing, and curing process, or to choose product H21000, product H11500, product H21500, or other high-temperature resistant adhesive routes.
X. Common Misconceptions
A temperature range of 800-1000°C means that the product can be used continuously at 1000°C under full load.
The data shows that the bonding strength at 600°C is greater than 3 MPa. The strength may continue to decrease at higher temperatures. It should be evaluated based on actual load, safety factor, and time, and not just judged by the upper limit of the temperature resistance.
Three-component adhesives can be mixed randomly by proportion.
For three-component adhesives, the correct proportion should be confirmed according to the valid TDS, measured separately, and mixed in the correct order. Deviation in proportion or uneven mixing will result in incomplete curing and a decrease in high-temperature strength.
The higher the curing temperature, the higher the strength.
Curing should be carried out by gradually heating to 170°C in the furnace.